Open Access

Table 1

Maximum distortion of femoral components under different build orientations.

Case Build orientations (axis-degree) Maximum distortion value (mm) Reduction of the max. distortion value of X-90° case compared to other rotation angles (mm) Different of maximum distortion of X-90° case compared to other rotation angles (%)
1 X−0° 0.34 0.11 32.35
2 X−30° 0.29 0.06 20.69
3 X−60° 0.49 0.26 53.06
4 X−90°* 0.23
5 Y−30° 0.61 0.38 62.30
6 Y−60° 0.55 0.32 58.18
7 Y−90° 0.41 0.23 50.00

Noted: * The smallest distortion case.