Open Access

Table 3

Overcut and machining depth for NaNO3 electrolyte.

Duty ratio Overcut (Theoretical) NaNO3 Overcut (Experimental) NaNO3 Depth (Theoretical) NaNO3 Depth (Experimental) NaNO3
30 27.9 26.68 14.3 12.8
40 37.2 33.148 18.8 18.3
50 46.5 50.251 23.5 21.5
60 55.8 57.201 28.2 28.7