Open Access

Table 5

The cycles to failure (to the nearest 100) and failure locations in the low cycle fatigue test.

Joint Cycles to failure Failure location
Z41 10900 SZ/TMAZ (RS)
Z61 20000 SZ/TMAZ (RS)
Z81 16000 HAZ (RS)
Z82 6000 TMAZ/SZ (AS)
Z84 2800 TMAZ/SZ (AS)

Current usage metrics show cumulative count of Article Views (full-text article views including HTML views, PDF and ePub downloads, according to the available data) and Abstracts Views on Vision4Press platform.

Data correspond to usage on the plateform after 2015. The current usage metrics is available 48-96 hours after online publication and is updated daily on week days.