Open Access

Table 8

Experimental results of SCM400 steel grinding process [11].

Trial. Cutting parameter Response
n (rev/min) f (mm/rev) ar (mm) Ra (μm) Rz (μm) MRR (mm3/min)
A1 400 0.05 0.01 0.51 2.06 82.439
A2 400 0.075 0.015 0.73 4.52 105.976
A3 400 0.09 0.02 0.59 4.24 169.533
A4 600 0.05 0.015 0.38 1.77 70.650
A5 600 0.075 0.02 0.42 3.53 141.277
A6 600 0.09 0.01 0.76 2.12 84.795
A7 800 0.05 0.02 0.39 2.35 94.185
A8 800 0.075 0.01 0.59 1.97 70.662
A9 800 0.09 0.015 0.64 3.18 127.171