Experimental results.

Expt.No. Current(A) Gap Voltage(V) Pulse on time(μs) MRR(mm3/min) TWR(mm3/min)
1 10 40 100 0.033 0.015
2 10 45 500 0.040 0.019
3 10 50 1000 0.026 0.022
4 10 55 1500 0.020 0.019
5 20 40 500 0.046 0.019
6 20 45 100 0.066 0.022
7 20 50 1500 0.066 0.030
8 20 55 1000 0.066 0.037
9 30 40 1000 0.079 0.030
10 30 45 1500 0.086 0.033
11 30 50 100 0.099 0.048
12 30 55 500 0.113 0.048
13 40 40 1500 0.093 0.037
14 40 45 1000 0.113 0.048
15 40 50 500 0.139 0.067
16 40 55 100 0.139 0.070