Fig. 10
Download original image
Pressure sensor signal for failure detection during fatigue testing. The plot shows the voltage output corresponding to the pressure level during cyclic deflection. The three signals before failure (left) show the characteristic progress of the bistable deflection. The signals after failure (right) indicate a clear and permanent drop in peak voltage, which was used as the criterion to determine the exact moment of fracture.