Open Access
Table 1.
Parameters for numerical computations; source [15].
The 1DOF tool | ||
Natural frequency of 1DOF tool | ωnx | 5793 rads−1 |
Mass of 1DOF tool | m | 0.03993 kg |
Damping ratio of 1DOF tool | ξx | 0.011 |
Tangential cutting coefficient | Ctan | 6 × 108 Nm−1−γ |
Tangential to normal cutting coefficient ratio | X | 0.33333 |
Feed exponent in the cutting force law | γ | 1 |
Number of teeth | N | 2 |
The symmetric 2DOF tool | ||
Natural frequencies of 2DOF symmetric tool | ωnx = ωny | 5793 rads−1 |
Mass of 2DOF tool | mx = my | 0.03993 kg |
Damping ratio of 2DOF tool | ξx = ξy | 0.011 |
Tangential cutting coefficient | Ctan | 6 × 108 Nm−1−γ |
Tangential to normal cutting coefficient ratio | X | 0.33333 |
Feed exponent in the cutting force law | γ | 1 |
Number of teeth | N | 2 |