Open Access

Table 7

Validation experiments for the percentage of suspension volume ( and ).

Confirmatory tests (CT) Suspension parameters Response variables

Garnet (#80) Al2O3 (#80)
ωp (%) ωa (%) Experimental model % Error % Error
CT1 0.73 3.5 99.5 98.697 0.807 98 98.374 0.004
CT2 0.74 4 99 97.568 1.446 98.5 98.718 0.002
CT3 0.76 4.5 97 96.539 0.475 99 99.226 0.002
CT4 0.78 6 95 93.052 2.051 99 99.357 0.004
CT5 0.79 6.7 93 91.431 1.687 100 99.317 0.007
Mean % error 1.293 0.019