Experimental results predicted values of responses under nano fluid mixed MQL condition using AlCrN coated carbide drill.

Exp. no Level of the process parameters Experimental results Predicted values



  N f' P Np Fz (N) Θ (°C) Ra (μm) VB (mm) Fz (N) Θ (°C) Ra (μm) VB (mm)
1 1 1 1 1 530 257 1.07 45 524 253 1.12 43
2 1 2 2 2 555 240 1.17 54 564 236 1.21 54
3 1 3 3 3 590 224 1.18 59 582 218 1.23 57
4 2 1 2 3 490 263 0.92 43 491 269 0.71 44
5 2 2 3 1 525 270 1.1 59 534 286 1.02 61
6 2 3 1 2 570 287 0.98 69 566 288 0.98 70
7 3 1 3 2 465 329 0.36 53 460 319 0.51 51
8 3 2 1 3 510 317 0.47 68 515 321 0.54 67
9 3 3 2 1 540 346 0.86 78 535 338 0.79 77